Fuse‑Arrester Combi Unit

Fuse‑Arrester Combi Unit

The "Combi Unit" manufactured by Yueqing Jasco is designed and produced in strict accordance with international IEC standards. It integrates a fuse unit with a gapless zinc-oxide surge arrester, creating a pole-mounted device specifically engineered for 11kV and 33kV overhead distribution networks.
Send Inquiry

Product Description

 

The "Combi Unit" manufactured by Yueqing Jasco is designed and produced in strict accordance with international IEC standards. It integrates a fuse unit with a gapless zinc-oxide surge arrester, creating a pole-mounted device specifically engineered for 11kV and 33kV overhead distribution networks.

The "Combi Unit" fuse assembly comprises a silicone rubber insulator, a UV-resistant epoxy-fiberglass arc-extinguishing fuse tube, and silver-plated copper components. Upon a fault, the fuse tube automatically drops out to create a visible break, facilitating safe inspection and ensuring the safety of maintenance personnel.

The mounting bracket features a hot-dip galvanized finish and a reinforced design, enabling it to withstand high wind loads and ensuring long-term mechanical durability; the support bracket utilizes a structure consisting of a fiberglass core rod encapsulated in silicone rubber, offering exceptional mechanical bending strength. The "Combi Unit" remains unaffected by harsh outdoor environments - such as those with salt spray, high temperatures, high humidity, or heavy pollution - and offers customizable parameters to suit specific application scenarios, including high-altitude installations.

This integrated system replaces traditional discrete components, thereby simplifying transformer installation design and providing comprehensive protection for pole-mounted distribution transformers against short circuits, overloads, lightning strikes, and voltage surges. The fuse-arrester combination unit undergoes rigorous factory testing and comes with third-party test reports that meet the requirements for international tenders and on-site acceptance.

1

 

Technical Data Sheet

 

Item

11 (11 kV Combi Unit)

33 (33 kV Combi Unit)

Nominal System Voltage

11 kV

33 kV

Rated Equipment Voltage

12 kV

36 kV

Rated Frequency

50 Hz

50 Hz

Rated Fuse Current

100 A

100 A

Rated Short‑circuit Breaking Current of Fuse

8 kA

Customized as per client's requirement

MCOV of Surge Arrester

9.6 kV

Customized according to system requirement

Creepage Distance of Post Insulator

≥384 mm

≥1152 mm

Lightning Impulse Withstand Voltage

95 kV

≥200 kV

Bending Failure Load of Post Insulator

≥5 kN

≥5 kN

Thickness of Galvanized Coating for Support Frame

70‑100 μm

70‑100 μm

Maximum Applicable Altitude

1800 m

1800 m

Applicable Pollution Class

Up to Class IV

Up to Class IV

Design Service Life

20‑30 years

20‑30 years

Mounting Method

Pole‑mounted

Pole‑mounted

Key Configuration

Drop‑out fuse + ZnO arrester, mechanical interlock, arrester disconnector & fault indicator, silver‑plated copper contacts

Drop‑out fuse + ZnO arrester, mechanical interlock, arrester disconnector & fault indicator, silver‑plated copper contacts

Applicable Standards

IEC 60099‑4, IEC 60282‑2, IEC 60815, IEC 60076, ISO 1461

IEC 60099‑4, IEC 60282‑2, IEC 60815, IEC 60076, ISO 1461

 

Product Advantage

01/

The integrated design saves space, reduces installation and implementation time, and lowers costs.

02/

Dual protection: Features integrated protection against short circuits, overloads, and overcurrents, ensuring comprehensive protection for distribution transformers and minimizing the risk of equipment failure.

03/

Utilizes silver-plated contacts, silicone rubber insulation, and corrosion-resistant metal components; offers excellent weather and corrosion resistance, ensuring stable operation and reducing long-term maintenance costs.

04/

Suitable for environments with Pollution Level IV and altitudes up to 1,800 meters; customized solutions are available for higher altitudes and specific rated current requirements.

05/

Factory-direct supply options include neutral packaging and custom branding; supports consolidated shipping with other power distribution equipment.

 

Operating Environment Conditions

 

1. Ambient temperature: -40°C to +40°C

2. Altitude: ≤1800m (customizable for higher altitudes)

3. Maximum wind speed: ≤35m/s

4. Pollution level: Up to Class IV

5. Free from severe vibration, explosive hazards, and highly corrosive media.

 

FAQ

 

Q: Can large orders be customized?

A: Yes. As the original manufacturer, JASCO offers neutral packaging, custom labeling, and shipping label services, and also supports the customization of certain technical specifications.

Q: What standards does the product follow? What certificates & reports can you supply?

A: IEC CE ISO....

Q: What are the requirements for installing the combi unit?

A: The unit is designed for installation at power distribution openings. During installation, adequate spacing must be maintained between phases to ensure safe electrical insulation. The installation work must comply with local grid regulations.

 

Hot Tags: fuse‑arrester combi unit, China fuse‑arrester combi unit manufacturers, suppliers, factory

Looking for High-quality Electrical Equipment?

Driven by continuous technical and service innovation, we focus on product reliability and project performance, striving for sustainable win‑win partnerships and consistent value for overseas power‑infrastructure projects.

Send Inquiry